Heating test of cycloid reducer

XNUMX. Environmental conditions
1. The measurement of the temperature rise of the cycloid reducer should be carried out in a room that is not affected by the external temperature. The indoor ambient temperature should be in the range of 5~40 °C. Should the indoor air circulate freely? The forced circulation method is not allowed.
2. Temperature measuring point
The temperature measurement point should be selected in the position where the thermometer can contact the lubricating oil of the cycloid reducer.
XNUMX. Thermometer
The graduation value is 0.5°C.

XNUMX. Measurement method
1. Determination of working temperature
The measurement of the temperature rise of the reducer under test is generally carried out together with the measurement of the bearing capacity and transmission power of the reducer, or it can be carried out independently. Operating temperature.
2. Determination of ambient temperature
Place a thermometer 1.5m away from the surface of the cycloid reducer under test. The height of the thermometer measuring point from the ground is the same as the axis of the reducer. The placement of the thermometer should not be affected by external radiant heat and airflow. should be read together with the reading of the operating temperature value.
Four, temperature rise accounting
The temperature rise is calculated according to the formula: 
In the formula: Δt——the temperature rise of the reducer, ℃
Working temperature of cycloid reducer at extra speed and extra input power, ℃
Ambient temperature, °C. t2—— t1—— Δt=t1–t2