Introduction to inspection and maintenance of cycloid reducer

How to effectively check and maintain the reducer.Different lubricating oils are not allowed to be mixed with each other.The position of the oil level plug, oil drain plug and breather is determined by the installation position.Their relative positions can be determined by referring to the installation position diagram of the reducer.The following small series will mainly explain through the replacement of oil, the inspection of oil level, the reducer with oil level plug, the inspection of oil and other aspects.gear reducer, cycloid reducer, worm gear reducer

1. For the reducer with oil level plug

Check the oil level, whether it is qualified; install the oil level plug.

2. Matters needing attention

Inject new oil of the same brand; the amount of oil should be consistent with the installation position; check the oil level at the oil level plug; tighten the oil level plug and breather; the reducer should remain warm when changing the oil; Put an oil pan below; open the oil level plug, breather and oil drain plug; drain all the oil; install the oil drain plug.gear reducer, cycloid reducer, worm gear reducer

3. Check the oil level

Cut off the power to prevent electric shock!Wait for the reducer to cool down; remove the oil level plug to check if the oil is full; install the oil level plug.

4. Oil replacement

After cooling, the viscosity of the oil increases, and it is difficult to drain the oil. The reducer should be changed at the operating temperature.Cut off the power to prevent electric shock!Wait for the gear unit to cool down until there is no danger of burning!gear reducer, cycloid reducer, worm gear reducer

5. Oil inspection

Cut off the power to prevent electric shock!Wait for the reducer to cool down; open the oil drain plug and take an oil sample; check the viscosity index of the oil; if the oil is obviously turbid, it is recommended to replace it as soon as possible.